EDS Embedded Data Systems HA7Net Ethernet 1 Wire Host Adapter RETAIL 5

$ 31.67

Availability: 85 in stock
  • Condition: Device has been tested and is fully operational. Unit has to be reset and brought back to default settings. Find instructions in auction description.
  • Refund will be given as: Money Back
  • All returns accepted: Returns Accepted
  • Item must be returned within: 14 Days
  • Return shipping will be paid by: Buyer
  • Restocking Fee: 20%

    Description

    EMBEDDED DATA SYSTEMS
    HA7NET
    FREE SHIPPING
    2-3 Day Priority Shipping
    **USED**
    Information
    Manufacturer
    EDS
    Model Number
    HA7NET
    Product Detail
    **********************************************************************************************
    Device was taken out from a working environment. SLIGHTLY USED
    RETAIL PRICE: 5
    This auction DOES NOT include any ACCESSORIES/POWER SUPPLY. "REQUIRES 6-12VDC"
    UNIT HAS TO BE DEFAULTED TO ORIGINAL SETTINGS "At your request we can default device for an additional .00"
    SEE INSTRUCTIONS BELOW
    Additional Information
    Accepted Payment Methods
    Paypal
    Shipping
    United States
    Return Policy
    14 Days return. Buyer pays shipping.
    THANK YOU FOR SHOPPING
    Factory Reset
    Resetting the HA7Net to factory defaults will set the following configuration values:
    • IP Address: First tries DHCP, if no DHCP server found, then defaults to 192.168.0.250
    • Admin User: admin
    • Admin Password: eds
    • Http Port: 80
    • Https Port: 443
    The reset procedure is performed as follows:
    Start by unplugging the HA7Net, and then remove the top cover. Inside, you will see two metallic pads near the center of the PCB labeled 'Factory Reset'.
    Use an appropriate tool (tweezers, paper clip, etc.) to short these two pads together. While shorting these two contacts, power-up the HA7Net.
    ** Keep the two contacts shorted together until you see the green and red LEDs on the front of the HA7Net begin to flash alternately. **
    At this point you have triggered the HA7Net to perform a reset, and you can remove the short.
    Overall, the reset will take one to two minutes to complete, as the HA7Net will generate a new SSL certificate during the process...a very computationally intensive task. After the reset is complete, the LEDs will return to normal operation, and the HA7Net should operate using the default configuration values given above.
    Power Supply Requirements
    The HA7Net is fitted with a 2.5mm power jack suitable for connection to any 6-12 Volt DC power supply having a F2 (2.5mmID x 5.5mmOD) female type plug wired for positive polarity on the center conductor. The power supply should capable of delivering 500mA