-40%

XY-L10A Lithium Battery Charge Controller Protection Board 6-60V LCD Display US

$ 5.08

Availability: 101 in stock
  • Brand: Unbranded
  • Nominal Current Rating: 10 A
  • Installation Area: Indoor
  • Model: XY-L10A
  • Device Function: Voltage Regulator
  • Condition: New
  • Country/Region of Manufacture: China
  • Conversion Direction: Step-Down
  • Nominal Voltage Rating (DC): 6-60V
  • Product Type: Power Regulator
  • Maximum Continuous Output Current: 10A
  • Custom Bundle: No
  • Input Voltage Range: 6V-60V
  • Return shipping will be paid by: Seller
  • Maximum Peak Output Current: 10A
  • Type: Electronic Voltage Regulator
  • Current Conversion: DC to DC
  • Item must be returned within: 30 Days
  • MPN: Does Not Apply
  • All returns accepted: Returns Accepted
  • Modified Item: No
  • Output Voltage Rating (DC): 6-60V
  • Refund will be given as: Money Back

    Description

    Specification
    :
    100% brand new with high quality
    Control Voltage: DC 6V-60V
    Control Current: 10A (Max)
    Control Precision: 0.1V
    Output Type: Direct output
    Voltage Error: 0.1V
    Suitable for battery: Storage Battery, Lithium battery
    Physical Size: Approx.79 x 42 x 18mm
    Application: Car, Electric car, Factory, Communications room, Radar station, Computer room
    Features
    :
    LCD display
    Display battery voltage
    Percentage of electricity
    Time adjustable
    Working status indicator
    Support UART Set
    Automatic protection battery
    Function
    :
    Automatic Charge control function:
    By setting the Upper limit voltage volt-HI: 'UP'; Lower limit voltage volt-LI: 'dn'
    The relay turns ON and the charger starts charging for the battery when Current battery voltage is less than Lower limit voltage 'dn'.
    The relay turns OFF and complete an automatic charge when Current battery voltage is more than Upper limit voltage 'UP'.
    Charge Time Control Function:
    How to enable the time control function:
    It will enable time control function by setting parameter 'OP' is not '0' after entering the parameter set menu.
    'OP' default parameter is:'--:--h', the default does not turn on time control function
    After enable Time Control Function ('OP' is not equal to '0'):
    Relay will turn ON and the charger starts charging the battery and the system starts timing when Current battery voltage is less than Lower limit voltage 'dn'.
    Relay will turn OFF and end charging if Current battery voltage is more than Upper limit voltage 'UP' during timing.
    Relay will turn OFF and end charging if Current battery voltage is less than Upper limit voltage 'UP' but the time ('OP') has ended.
    Relay will keep ON and charging if Current battery voltage is less than Lower limit voltage 'dn' even though the time ('OP') has ended. Module will automatically turn off the charging time control function. And flashing 'H: ER' on screen to remind users that time parameter settings are unreasonable. Press any key to stop flashing.
    Note
    : Time format: 00:59 (00 is hours, 59 is minutes) The maximum time is 99:59 which is about 100 hours.
    UART communication and parameter settings:
    The system supports UART data upload and parameter setting functions (TTL level)
    UART: 115200, 8, 1
    NO.
    Command
    Function
    1
    ON
    Relays Enable
    2
    OFF
    Relays Disable
    3
    Start
    Start data upload
    4
    Stop
    Stop data upload
    5
    Read
    Read the parameter setting
    6
    dw10.0
    Set volt-LI:'dn'
    7
    up20.0
    Set volt-HI:'UP'
    8
    xx:xx
    Set the charge time 'OP'. 00:00 is   used to stop charge time
    Set the charge time 'OP'. 00:00 is   used to stop charge time
    Data upload message format
    Battery voltage + battery percentage + charging time + charging status
    12.0V, 020%, 00:10, OP
    Set Parameter:
    LCD will display 'SET' after enter set parameter menu by long press button 'SET'.
    Switch the set parameters by short pressing button 'SET'.
    Set parameter value by long or short pressing button 'UP' and 'DOWN'.
    Repeat step 2 and step 3 if need to set other parameters.
    Automatically save and exit the setup menu by long press button 'SET' after set all parameters.
    Button description:
    Long press: keep press button for more than 3second.
    In the normal display interface
    Display the currently set parameters when short press button 'SET'
    Switch display charging percentage and charging time when short press button 'UP'
    Enable Relay ON or OFF when short press button 'DOWN'. Relay will OFF and display OFF if disable relay.
    Set the status of the LCD backlight (L-P) when long press button 'UP'.
    OFF: The backlight will keep bright.
    ON: Backlight will be automatically turned OFF after 5-10 second.
    Long press 'SET' button to enter the parameter settings menu.
    Calculation voltage percentage:
    Voltage percentage = battery voltage/(volt-HI – volt-LI)
    Additional Features:
    Charging time recording function: The product will record a full charge time when the charging time control is not turned on. Flashing shows the charging time when entering the time display interface. The data will be emptied when exit the time display interface or the next charge is turned on (the relay is turned on)
    Automatic parameter detection: The system will flash 'ERR' to indicate the reminder when the parameter is set and exiting but Lower limit voltage 'dn' more than Upper limit voltage 'UP'.
    Battery connection detection: This product is attached to the battery. If the battery is not connected, the system will display 'nbE' on the lower line to remind you
    Package Included:
    1 xXY-L10A  Lithium Battery Charge Controller Protection Board 6-60V LCD Display
    4 x White isolation seat
    Instructions are
    NOT
    included. We don't provide technical assistance please make sure that you are familiar with the product before purchasing.